Central
LWA 100 – Technical Data

  • Type

    Product Number

    221470

    Width

    510 mm

    Height

    1290 mm

    Depth

    510 mm

    Air flow rate

    60-130 m³/h

    Technical data

    Energy efficiency class, DHW heating (extract air), load profile M

    A

    Rated capacity

    100 l

    HP DHW temperature

    55 °C

    Max. DHW temperature

    80 °C

    Electric emergency/booster heater

    3 kW

    Nominal DHW temperature (EN 16147)

    55 °C

    Nominal load profile (EN16147)

    M

    Maximum available amount of DHW at 40 °C (EN 16147 / A20 extract air)

    138 l

    Average heating output (EN 16147 / A20 extract air)

    0,80 kW

    Heat-up time (EN 16147 / A20 extract air)

    7,15 h

    Average heat pump power consumption (EN 16147 / A20 extract air)

    0,30 kW

    Power consumption, standby period (EN 16147 / A20 extract air)

    0,017 kW

    Performance factor (EN 16147 / A20 extract air)

    2,26

    Air connector diameter

    125 mm

    Refrigerant

    R290

    Refrigerant capacity

    0,15 kg

    Application range min./max.

    15...30 °C

    Weight

    65 kg

    Sound power level (EN 12102)

    45 dB(A)

    Filter class

    ISO Coarse > 30 % (G2)

    Technical data and product variants

    For further details and product variants please refer to data sheet.

    Download as PDF